How Many Vents?

Balance is the key to having an efficient attic ventilation system.  When balanced, a properly designed ventilation system will assure a continuous supply of air moves through the attic space, fighting off heat and moisture. Calculating the correct number of exhaust and intake vents is simple and will ensure you have an effective, balanced system.  

The first step in determining how many vents you need is to calculate the Net Free Area (NFA) required. Most codes use the 1/300 rule for minimum residential attic ventilation recommendations. This means that for every 300 square feet of enclosed attic space, 1 square foot of ventilation is required – with half at the upper portion (exhaust vents) and half in the lower portion (intake vents). This formula is traditionally used for static roof vents which are rated for Net Free Area in terms of square inches. 

Let’s go through an example… For a home with 2000 square feet of attic floor space, you’ll first divide 2000 by 300 (2000 ÷ 300 = 6.66). You need 6.66 square feet of attic ventilation. Since you want a balanced system, you divide by 2 so that half of the ventilation is intake and half is exhaust. Thus, 6.66 ÷ 2 = 3.33 square feet of attic ventilation for intake and 3.33 square feet of attic ventilation for exhaust. Because vents are rated in square inches, you need to convert the square feet required to square inches. This is accomplished by taking the square feet recommended and multiplying by 144(The number of square inches in a square foot). Thus, 3.33 X 144 = 480 square inches of attic ventilation is required for intake and 480 square inches for exhaust.

Once the recommended amount of Net Free Area is known and the type of vents have been selected, you can determine how many vents you will need. The next step is to divide the NFA required by the NFA rating of the vent. In our 2000 square feet example, we determined we needed 480 square inches for intake & 480 square inches for exhaust. For this example, let’s use the Lomanco 750 Slant Back Vent (50 square inches NFA) for the exhaust vents & the Deck-Air DA-4 (36 square inches NFA) for the intake vents. To calculate the number of 750 vents needed, divide 480 by 50 to get 9.6 vents. Rounding up, you would need ten (10) 750 Vents. Because you always want your intake NFA to meet or exceed the amount of exhaust NFA, we will take the amount of exhaust NFA provided and divide by the NFA rating of the Deck-Air. To calculate the number of Deck-Air Vents needed, divide 500 (10 X 50) by 36 to get 13.9 vents. Thus, you would need 14 Deck-Air Vents.  

If your head is now spinning from the calculations, don’t worry Lomanco has the tools needed to determine the number of vents needed (no calculator required!) Use the online ventilation calculator or download the Vent Selector App and skip the math.

NOTICE

Some local building codes require that 1 square foot of ventilation be provided for every 150 square feet of attic space.  Please check with your local building code office to ensure compliance to local requirements.

Primary Sidebar

Ventilation Resources

  • Resources
  • Support

Ventilation Articles

What Is Ventilation?

Why Ventilate?

What Is Ice Damming?

Vent Selector App

Why Lomanco?

Three Must Do Steps…

Conserve Energy…

Your Crawlspace?

Lomanco Vents

Facebook• © 2005–2025 · Lomanco, Inc. • YouTube

  • Home
  • About Us
  • AMM Login
  • Staff Login
  • Contact
Lomanco Vents
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}